AS400 Cards provide dry contacts for a remote shutdown and monitoring of an UPS. It is frequently used along with PLCs and signal control panels. Information delivered can be: UPS failure, alarms, main failure, bypass, low battery, UPS on. AS400 Card for: VFI RT, VFI PRT, VFI TCP, VFI TP 3/1, VFI 6000-10000 TGB/TGS, VFI 6000-10000 RTG(S)
Provides contact closure for monitoring UPS Offer different dry-contacts Suitable for IBM server, Personal PC and workstationsequipment’s, auto-controlled industrial equipment andcommunication applications. AS400 Cards provide clean dry contacts for remote shutdown and monitoring of a UPS. It is frequently used along with PLCs and signal control panels. Information delivered are UPS failure, Alarm, Main Fail, Bypass, Battery Low, UPS On. Using AS/400 it possible to shutdown UPS remotely. Solution requires external 12V/24VDC source for a high signal with max 1A. Pin assignment is available in User’s Manual. AS400 Card for: VI RT
AS/400 Cards provide clean dry contacts for remote shutdown and monitoring of a UPS. It is frequently used along with PLCs and signal control panels. Information delivered are UPS failure, Alarm, Main Fail, Bypass, Battery Low, UPS On. Using AS/400 it possible to shutdown UPS remotely. Solution requires external 12V/24VDC source for a high signal. Pin assignment is available in User’s Manual. AS/400 Card for: VFI LCD, VFI C LCD, VFI RM, VFI CRM, VFI RMG, VFI CT, VFI CG, VFI CP, VFI CPG
The PowerWalker ATS (Automatic Transfer Switch) also known as STS (Static Transfer Switch) is designed with two independent power inlets to supply power to the load from primary power source. Should primary power source fail, the secondary will automatically backup the connected equipment without any interruption. The transfer time from one to another is seamless to the connected equipment.
Selectable input voltage range for home appliances and personal computers Time Delay function eliminates transients that can affect connected equipment Microprocessor Control guarantees high reliability
The PowerWalker BMS Card is an accessory for the LiFe Battery System. It provides communication between the LiFe Battery System and the connected equipment:
Typical applications are routers and switches, signal amplifiers and repeaters, POE systems, access points, security systems, smart home control panels, VoIP phones, IP cameras, modems, decoders, media players, medical monitors and many other 12VDC (max. 25W) devices. Nominal load 12W constant. Maximum load/overload capacity up to 25W using coaxial DC connector (OD 5.5mm / ID 2.5mm).
EMD (environmental monitoring device) for NMC Card is a connectivity devices for remote monitoring of temperature and humidity. It provides dry contacts to communicate with compatible devices such as security system or alarm system.
EMD (environmental monitoring device) for SNMP Card 2 is a connectivity devices for remote monitoring of temperature and humidity. It provides dry contacts to communicate with compatible devices such as security system or alarm system.
EMD (environmental monitoring device) for SNMP Manager is a connectivity devices for remote monitoring of temperature and humidity. It provides dry contacts to communicate with compatible devices such as security system or alarm system.
Energy Meter incl. Modbus card for energy meter With the Energy-Meter + the included Modbus-Card the Solar Inverters SVN series can be easily integrated into the existing household system. Equipped with the Modbus-Card, the Solar Inverter can be connected to the energy meter through a RS485 communication port. You can monitor the power generation and the charging of the batteries.